Stream· 500 ms
PLC-01Main Line Controller A1
230.4V
12/12
214evt/m
Plant A · Tehran · Shift 1
12 devices are talking.
3 of them need you right now.
ScadaView polls every PLC, VFD, robot and sensor on the LAN and turns raw registers into a picture an operator can read in one glance. Click any node on the floor to drill in.
Availability
66.7%
8 of 12 OK
OEE · 24h
84.2%
↑ 2.1 vs yesterday
Active power
274kW
↓ 6.4 vs avg
Comm. health
99.993%
171 errors / 2422k polls
LIVE·500 ms poll
10.40.0.0/16 · 12 nodes
Device status
12 nodes reporting
67%
OK
Operational8
Warning1
Error1
Maintenance1
Offline1
Shift targets
Output84.0 / 90
Quality99.2 / 99
Uptime66.7 / 98
Plant performance (24h)
OEE = Availability × Performance × Quality
Availability
94.8%
Performance
92.1%
Quality
99.2%
Power draw (24h)
Main distribution panel — PWR-10
Peak 298 kW @ 12:40
Current
274.4kW
Today
4,812kWh
Cost est.
$ 384
VFD-03Conveyor VFD 03
Z3·10.40.1.45·uptime 410d
WLD-04MIG Welding Cell 04
Z4·10.40.1.58·uptime 63d
COOL-11Chiller Unit 11
Z8·10.40.2.33·uptime 0d
PLC-01Main Line Controller A1
Z2·10.40.1.21·uptime 268d
RBT-02Pick & Place Robot 02
Z2·10.40.1.32·uptime 88d
FRN-05Heat Treatment Furnace 05
Z5·10.40.2.11·uptime 504d
L-2841Polling cycle 184,213 complete. 128 I/O points read, 0 errors.
11:43:24·Main Line Controller A1
L-2840Set Output Frequency → 50.00 Hz (was 48.7 Hz). Recipe: standard_assembly_2024.
11:41:24·Conveyor VFD 03·@m.rasooli
L-2839Recipe R-2284 started. Hold time 124 min, target 825 °C.
11:40:24·Heat Treatment Furnace 05·@recipe
L-2838Heatsink temperature 72.4 °C crossed WARN threshold (70 °C).
11:36:24·Conveyor VFD 03
L-2837Set Demand Limit → 480 A (was 500 A).
11:33:24·Main Power Distribution 10·@m.rasooli
L-2836Operator acknowledged maintenance window WO-4412.
11:30:24·Operator Station 07·@h.ahmadi
L-2835E0921 — Wire feed stall. Cell halted. Manual reset required.
11:22:24·MIG Welding Cell 04
L-2834HMI-07 transitioned to MAINTENANCE mode for scheduled calibration.
11:18:24·Operator Station 07
Plant zones
8 production zones · 12 nodes
Tap a zone to focus the floor plan on that area.
Z1
Receiving
0/0operational
Z2
Assembly Line A
2/3operational
Z3
Assembly Line B
1/2operational
Z4
Welding Cell
0/1operational
Z5
Heat Treatment
1/1operational
Z6
Quality Lab
1/1operational
Z7
Shipping
1/1operational
Z8
Utilities
2/3operational
Two-way TCP/IP
The page decides what to compute locally — voltage scaling, clock sync, conversion tables — and only ships the values the operator actually changed.
On-demand refresh
No noisy WebSockets. Each poll cycle asks only the registers the operator is looking at, in the order they need them.
Fast historical store
Modern time-series backend with sort-by-time, multi-key filter, and full-text on tag, error code, recipe and operator.